diff options
Diffstat (limited to 'docs/Probe_Calibrate.md')
-rw-r--r-- | docs/Probe_Calibrate.md | 15 |
1 files changed, 15 insertions, 0 deletions
diff --git a/docs/Probe_Calibrate.md b/docs/Probe_Calibrate.md index f7e62b4c..5ec06bda 100644 --- a/docs/Probe_Calibrate.md +++ b/docs/Probe_Calibrate.md @@ -70,6 +70,21 @@ results to the config file with: SAVE_CONFIG ``` +Note that if a change is made to the printer's motion system, hotend +position, or probe location then it will invalidate the results of +PROBE_CALIBRATE. + +If the probe has an X or Y offset and the bed tilt is changed (eg, by +adjusting bed screws, running DELTA_CALIBRATE, running Z_TILT_ADJUST, +running QUAD_GANTRY_LEVEL, or similar) then it will invalidate the +results of PROBE_CALIBRATE. After making any of the above adjustments +it will be necessary to run PROBE_CALIBRATE again. + +If the results of PROBE_CALIBRATE are invalidated, then any previous +[bed mesh](Bed_Mesh.md) results that were obtained using the probe are +also invalidated - it will be necessary to rerun BED_MESH_CALIBRATE +after recalibrating the probe. + # Repeatability check After calibrating the probe X, Y, and Z offsets it is a good idea to |