aboutsummaryrefslogtreecommitdiffstats
path: root/docs/Config_Reference.md
diff options
context:
space:
mode:
Diffstat (limited to 'docs/Config_Reference.md')
-rw-r--r--docs/Config_Reference.md59
1 files changed, 59 insertions, 0 deletions
diff --git a/docs/Config_Reference.md b/docs/Config_Reference.md
index b192e736..9be53dfa 100644
--- a/docs/Config_Reference.md
+++ b/docs/Config_Reference.md
@@ -2401,6 +2401,65 @@ temperature sensors that are reported via the M105 command.
# parameter.
```
+### [temperature_probe]
+
+Reports probe coil temperature. Includes optional thermal drift
+calibration for eddy current based probes. A `[temperature_probe]`
+section may be linked to a `[probe_eddy_current]` by using the same
+postfix for both sections.
+
+```
+[temperature_probe my_probe]
+#sensor_type:
+#sensor_pin:
+#min_temp:
+#max_temp:
+# Temperature sensor configuration.
+# See the "extruder" section for the definition of the above
+# parameters.
+#smooth_time:
+# A time value (in seconds) over which temperature measurements will
+# be smoothed to reduce the impact of measurement noise. The default
+# is 2.0 seconds.
+#gcode_id:
+# See the "heater_generic" section for the definition of this
+# parameter.
+#speed:
+# The travel speed [mm/s] for xy moves during calibration. Default
+# is the speed defined by the probe.
+#horizontal_move_z:
+# The z distance [mm] from the bed at which xy moves will occur
+# during calibration. Default is 2mm.
+#resting_z:
+# The z distance [mm] from the bed at which the tool will rest
+# to heat the probe coil during calibration. Default is .4mm
+#calibration_position:
+# The X, Y, Z position where the tool should be moved when
+# probe drift calibration initializes. This is the location
+# where the first manual probe will occur. If omitted, the
+# default behavior is not to move the tool prior to the first
+# manual probe.
+#calibration_bed_temp:
+# The maximum safe bed temperature (in C) used to heat the probe
+# during probe drift calibration. When set, the calibration
+# procedure will turn on the bed after the first sample is
+# taken. When the calibration procedure is complete the bed
+# temperature will be set to zero. When omitted the default
+# behavior is not to set the bed temperature.
+#calibration_extruder_temp:
+# The extruder temperature (in C) set probe during drift calibration.
+# When this option is supplied the procedure will wait for until the
+# specified temperature is reached before requesting the first manual
+# probe. When the calibration procedure is complete the extruder
+# temperature will be set to 0. When omitted the default behavior is
+# not to set the extruder temperature.
+#extruder_heating_z: 50.
+# The Z location where extruder heating will occur if the
+# "calibration_extruder_temp" option is set. Its recommended to heat
+# the extruder some distance from the bed to minimize its impact on
+# the probe coil temperature. The default is 50.
+```
+
## Temperature sensors
Klipper includes definitions for many types of temperature sensors.