docs: add initial temperature_probe documentation
Signed-off-by: Eric Callahan <arksine.code@gmail.com>
Diffstat (limited to 'docs/Config_Reference.md')
-rw-r--r-- | docs/Config_Reference.md | 59 |
1 files changed, 59 insertions, 0 deletions
diff --git a/docs/Config_Reference.md b/docs/Config_Reference.md index b192e736..9be53dfa 100644 --- a/docs/Config_Reference.md +++ b/docs/Config_Reference.md @@ -2401,6 +2401,65 @@ temperature sensors that are reported via the M105 command. # parameter. ``` +### [temperature_probe] + +Reports probe coil temperature. Includes optional thermal drift +calibration for eddy current based probes. A `[temperature_probe]` +section may be linked to a `[probe_eddy_current]` by using the same +postfix for both sections. + +``` +[temperature_probe my_probe] +#sensor_type: +#sensor_pin: +#min_temp: +#max_temp: +# Temperature sensor configuration. +# See the "extruder" section for the definition of the above +# parameters. +#smooth_time: +# A time value (in seconds) over which temperature measurements will +# be smoothed to reduce the impact of measurement noise. The default +# is 2.0 seconds. +#gcode_id: +# See the "heater_generic" section for the definition of this +# parameter. +#speed: +# The travel speed [mm/s] for xy moves during calibration. Default +# is the speed defined by the probe. +#horizontal_move_z: +# The z distance [mm] from the bed at which xy moves will occur +# during calibration. Default is 2mm. +#resting_z: +# The z distance [mm] from the bed at which the tool will rest +# to heat the probe coil during calibration. Default is .4mm +#calibration_position: +# The X, Y, Z position where the tool should be moved when +# probe drift calibration initializes. This is the location +# where the first manual probe will occur. If omitted, the +# default behavior is not to move the tool prior to the first +# manual probe. +#calibration_bed_temp: +# The maximum safe bed temperature (in C) used to heat the probe +# during probe drift calibration. When set, the calibration +# procedure will turn on the bed after the first sample is +# taken. When the calibration procedure is complete the bed +# temperature will be set to zero. When omitted the default +# behavior is not to set the bed temperature. +#calibration_extruder_temp: +# The extruder temperature (in C) set probe during drift calibration. +# When this option is supplied the procedure will wait for until the +# specified temperature is reached before requesting the first manual +# probe. When the calibration procedure is complete the extruder +# temperature will be set to 0. When omitted the default behavior is +# not to set the extruder temperature. +#extruder_heating_z: 50. +# The Z location where extruder heating will occur if the +# "calibration_extruder_temp" option is set. Its recommended to heat +# the extruder some distance from the bed to minimize its impact on +# the probe coil temperature. The default is 50. +``` + ## Temperature sensors Klipper includes definitions for many types of temperature sensors. |