1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
|
# Support for reading acceleration data from an LIS2DW chip
#
# Copyright (C) 2023 Zhou.XianMing <zhouxm@biqu3d.com>
# Copyright (C) 2020-2021 Kevin O'Connor <kevin@koconnor.net>
#
# This file may be distributed under the terms of the GNU GPLv3 license.
import logging, time, collections, threading, multiprocessing, os
from . import bus, motion_report, adxl345
# LIS2DW registers
REG_LIS2DW_WHO_AM_I_ADDR = 0x0F
REG_LIS2DW_CTRL_REG1_ADDR = 0x20
REG_LIS2DW_CTRL_REG2_ADDR = 0x21
REG_LIS2DW_CTRL_REG3_ADDR = 0x22
REG_LIS2DW_CTRL_REG6_ADDR = 0x25
REG_LIS2DW_STATUS_REG_ADDR = 0x27
REG_LIS2DW_OUT_XL_ADDR = 0x28
REG_LIS2DW_OUT_XH_ADDR = 0x29
REG_LIS2DW_OUT_YL_ADDR = 0x2A
REG_LIS2DW_OUT_YH_ADDR = 0x2B
REG_LIS2DW_OUT_ZL_ADDR = 0x2C
REG_LIS2DW_OUT_ZH_ADDR = 0x2D
REG_LIS2DW_FIFO_CTRL = 0x2E
REG_LIS2DW_FIFO_SAMPLES = 0x2F
REG_MOD_READ = 0x80
# REG_MOD_MULTI = 0x40
LIS2DW_DEV_ID = 0x44
FREEFALL_ACCEL = 9.80665
SCALE = FREEFALL_ACCEL * 1.952 / 4
Accel_Measurement = collections.namedtuple(
'Accel_Measurement', ('time', 'accel_x', 'accel_y', 'accel_z'))
MIN_MSG_TIME = 0.100
BYTES_PER_SAMPLE = 6
SAMPLES_PER_BLOCK = 8
# Printer class that controls LIS2DW chip
class LIS2DW:
def __init__(self, config):
self.printer = config.get_printer()
adxl345.AccelCommandHelper(config, self)
self.query_rate = 0
am = {'x': (0, SCALE), 'y': (1, SCALE), 'z': (2, SCALE),
'-x': (0, -SCALE), '-y': (1, -SCALE), '-z': (2, -SCALE)}
axes_map = config.getlist('axes_map', ('x','y','z'), count=3)
if any([a not in am for a in axes_map]):
raise config.error("Invalid lis2dw axes_map parameter")
self.axes_map = [am[a.strip()] for a in axes_map]
self.data_rate = 1600
# Measurement storage (accessed from background thread)
self.lock = threading.Lock()
self.raw_samples = []
# Setup mcu sensor_lis2dw bulk query code
self.spi = bus.MCU_SPI_from_config(config, 3, default_speed=5000000)
self.mcu = mcu = self.spi.get_mcu()
self.oid = oid = mcu.create_oid()
self.query_lis2dw_cmd = self.query_lis2dw_end_cmd = None
self.query_lis2dw_status_cmd = None
mcu.add_config_cmd("config_lis2dw oid=%d spi_oid=%d"
% (oid, self.spi.get_oid()))
mcu.add_config_cmd("query_lis2dw oid=%d clock=0 rest_ticks=0"
% (oid,), on_restart=True)
mcu.register_config_callback(self._build_config)
mcu.register_response(self._handle_lis2dw_data, "lis2dw_data", oid)
# Clock tracking
self.last_sequence = self.max_query_duration = 0
self.last_limit_count = self.last_error_count = 0
self.clock_sync = adxl345.ClockSyncRegression(self.mcu, 640)
# API server endpoints
self.api_dump = motion_report.APIDumpHelper(
self.printer, self._api_update, self._api_startstop, 0.100)
self.name = config.get_name().split()[-1]
wh = self.printer.lookup_object('webhooks')
wh.register_mux_endpoint("lis2dw/dump_lis2dw", "sensor", self.name,
self._handle_dump_lis2dw)
def _build_config(self):
cmdqueue = self.spi.get_command_queue()
self.query_lis2dw_cmd = self.mcu.lookup_command(
"query_lis2dw oid=%c clock=%u rest_ticks=%u", cq=cmdqueue)
self.query_lis2dw_end_cmd = self.mcu.lookup_query_command(
"query_lis2dw oid=%c clock=%u rest_ticks=%u",
"lis2dw_status oid=%c clock=%u query_ticks=%u next_sequence=%hu"
" buffered=%c fifo=%c limit_count=%hu", oid=self.oid, cq=cmdqueue)
self.query_lis2dw_status_cmd = self.mcu.lookup_query_command(
"query_lis2dw_status oid=%c",
"lis2dw_status oid=%c clock=%u query_ticks=%u next_sequence=%hu"
" buffered=%c fifo=%c limit_count=%hu", oid=self.oid, cq=cmdqueue)
def read_reg(self, reg):
params = self.spi.spi_transfer([reg | REG_MOD_READ, 0x00])
response = bytearray(params['response'])
return response[1]
def set_reg(self, reg, val, minclock=0):
self.spi.spi_send([reg, val & 0xFF], minclock=minclock)
stored_val = self.read_reg(reg)
if stored_val != val:
raise self.printer.command_error(
"Failed to set LIS2DW register [0x%x] to 0x%x: got 0x%x. "
"This is generally indicative of connection problems "
"(e.g. faulty wiring) or a faulty lis2dw chip." % (
reg, val, stored_val))
# Measurement collection
def is_measuring(self):
return self.query_rate > 0
def _handle_lis2dw_data(self, params):
with self.lock:
self.raw_samples.append(params)
def _extract_samples(self, raw_samples):
# Load variables to optimize inner loop below
(x_pos, x_scale), (y_pos, y_scale), (z_pos, z_scale) = self.axes_map
last_sequence = self.last_sequence
time_base, chip_base, inv_freq = self.clock_sync.get_time_translation()
# Process every message in raw_samples
count = seq = 0
samples = [None] * (len(raw_samples) * SAMPLES_PER_BLOCK)
for params in raw_samples:
seq_diff = (last_sequence - params['sequence']) & 0xffff
seq_diff -= (seq_diff & 0x8000) << 1
seq = last_sequence - seq_diff
d = bytearray(params['data'])
msg_cdiff = seq * SAMPLES_PER_BLOCK - chip_base
for i in range(len(d) // BYTES_PER_SAMPLE):
d_xyz = d[i*BYTES_PER_SAMPLE:(i+1)*BYTES_PER_SAMPLE]
xlow, xhigh, ylow, yhigh, zlow, zhigh = d_xyz
# Merge and perform twos-complement
rx = (((xhigh << 8) | xlow)) - ((xhigh & 0x80) << 9)
ry = (((yhigh << 8) | ylow)) - ((yhigh & 0x80) << 9)
rz = (((zhigh << 8) | zlow)) - ((zhigh & 0x80) << 9)
raw_xyz = (rx, ry, rz)
x = round(raw_xyz[x_pos] * x_scale, 6)
y = round(raw_xyz[y_pos] * y_scale, 6)
z = round(raw_xyz[z_pos] * z_scale, 6)
ptime = round(time_base + (msg_cdiff + i) * inv_freq, 6)
samples[count] = (ptime, x, y, z)
count += 1
self.clock_sync.set_last_chip_clock(seq * SAMPLES_PER_BLOCK + i)
del samples[count:]
return samples
def _update_clock(self, minclock=0):
# Query current state
for retry in range(5):
params = self.query_lis2dw_status_cmd.send([self.oid],
minclock=minclock)
fifo = params['fifo'] & 0x1f
if fifo <= 32:
break
else:
raise self.printer.command_error("Unable to query lis2dw fifo")
mcu_clock = self.mcu.clock32_to_clock64(params['clock'])
sequence = (self.last_sequence & ~0xffff) | params['next_sequence']
if sequence < self.last_sequence:
sequence += 0x10000
self.last_sequence = sequence
buffered = params['buffered']
limit_count = (self.last_limit_count & ~0xffff) | params['limit_count']
if limit_count < self.last_limit_count:
limit_count += 0x10000
self.last_limit_count = limit_count
duration = params['query_ticks']
if duration > self.max_query_duration:
# Skip measurement as a high query time could skew clock tracking
self.max_query_duration = max(2 * self.max_query_duration,
self.mcu.seconds_to_clock(.000005))
return
self.max_query_duration = 2 * duration
msg_count = (sequence * SAMPLES_PER_BLOCK
+ buffered // BYTES_PER_SAMPLE + fifo)
# The "chip clock" is the message counter plus .5 for average
# inaccuracy of query responses and plus .5 for assumed offset
# of lis2dw hw processing time.
chip_clock = msg_count + 1
self.clock_sync.update(mcu_clock + duration // 2, chip_clock)
def _start_measurements(self):
if self.is_measuring():
return
# In case of miswiring, testing LIS2DW device ID prevents treating
# noise or wrong signal as a correctly initialized device
dev_id = self.read_reg(REG_LIS2DW_WHO_AM_I_ADDR)
logging.info("lis2dw_dev_id: %x", dev_id)
if dev_id != LIS2DW_DEV_ID:
raise self.printer.command_error(
"Invalid lis2dw id (got %x vs %x).\n"
"This is generally indicative of connection problems\n"
"(e.g. faulty wiring) or a faulty lis2dw chip."
% (dev_id, LIS2DW_DEV_ID))
# Setup chip in requested query rate
# ODR/2, +-16g, low-pass filter, Low-noise abled
self.set_reg(REG_LIS2DW_CTRL_REG6_ADDR, 0x34)
# Continuous mode: If the FIFO is full
# the new sample overwrites the older sample.
self.set_reg(REG_LIS2DW_FIFO_CTRL, 0xC0)
# High-Performance / Low-Power mode 1600/200 Hz
# High-Performance Mode (14-bit resolution)
self.set_reg(REG_LIS2DW_CTRL_REG1_ADDR, 0x94)
# Setup samples
with self.lock:
self.raw_samples = []
# Start bulk reading
systime = self.printer.get_reactor().monotonic()
print_time = self.mcu.estimated_print_time(systime) + MIN_MSG_TIME
reqclock = self.mcu.print_time_to_clock(print_time)
rest_ticks = self.mcu.seconds_to_clock(4. / self.data_rate)
self.query_rate = self.data_rate
self.query_lis2dw_cmd.send([self.oid, reqclock, rest_ticks],
reqclock=reqclock)
logging.info("LIS2DW starting '%s' measurements", self.name)
# Initialize clock tracking
self.last_sequence = 0
self.last_limit_count = self.last_error_count = 0
self.clock_sync.reset(reqclock, 0)
self.max_query_duration = 1 << 31
self._update_clock(minclock=reqclock)
self.max_query_duration = 1 << 31
def _finish_measurements(self):
if not self.is_measuring():
return
# Halt bulk reading
params = self.query_lis2dw_end_cmd.send([self.oid, 0, 0])
self.query_rate = 0
with self.lock:
self.raw_samples = []
logging.info("LIS2DW finished '%s' measurements", self.name)
self.set_reg(REG_LIS2DW_FIFO_CTRL, 0x00)
# API interface
def _api_update(self, eventtime):
self._update_clock()
with self.lock:
raw_samples = self.raw_samples
self.raw_samples = []
if not raw_samples:
return {}
samples = self._extract_samples(raw_samples)
if not samples:
return {}
return {'data': samples, 'errors': self.last_error_count,
'overflows': self.last_limit_count}
def _api_startstop(self, is_start):
if is_start:
self._start_measurements()
else:
self._finish_measurements()
def _handle_dump_lis2dw(self, web_request):
self.api_dump.add_client(web_request)
hdr = ('time', 'x_acceleration', 'y_acceleration', 'z_acceleration')
web_request.send({'header': hdr})
def start_internal_client(self):
cconn = self.api_dump.add_internal_client()
return adxl345.AccelQueryHelper(self.printer, cconn)
def load_config(config):
return LIS2DW(config)
def load_config_prefix(config):
return LIS2DW(config)
|