aboutsummaryrefslogtreecommitdiffstats
path: root/klippy/extras/adc_temperature.py
diff options
context:
space:
mode:
Diffstat (limited to 'klippy/extras/adc_temperature.py')
-rw-r--r--klippy/extras/adc_temperature.py51
1 files changed, 49 insertions, 2 deletions
diff --git a/klippy/extras/adc_temperature.py b/klippy/extras/adc_temperature.py
index cb7b0e28..086f2858 100644
--- a/klippy/extras/adc_temperature.py
+++ b/klippy/extras/adc_temperature.py
@@ -119,6 +119,50 @@ class CustomLinearVoltage:
lv = LinearVoltage(config, self.params)
return PrinterADCtoTemperature(config, lv)
+
+######################################################################
+# Linear resistance to temperature converter
+######################################################################
+
+# Linear resistance calibrated with two temp measurements
+class LinearResistance:
+ def __init__(self, config, samples):
+ self.pullup = config.getfloat('pullup_resistor', 4700., above=0.)
+ try:
+ self.li = LinearInterpolate(samples)
+ except ValueError as e:
+ raise config.error("adc_temperature %s in heater %s" % (
+ str(e), config.get_name()))
+ def calc_temp(self, adc):
+ # Calculate temperature from adc
+ adc = max(.00001, min(.99999, adc))
+ r = self.pullup * adc / (1.0 - adc)
+ return self.li.interpolate(r)
+ def calc_adc(self, temp):
+ # Calculate adc reading from a temperature
+ r = self.li.reverse_interpolate(temp)
+ return r / (self.pullup + r)
+
+# Custom defined sensors from the config file
+class CustomLinearResistance:
+ def __init__(self, config):
+ self.name = " ".join(config.get_name().split()[1:])
+ self.samples = []
+ for i in range(1, 1000):
+ t = config.getfloat("temperature%d" % (i,), None)
+ if t is None:
+ break
+ r = config.getfloat("resistance%d" % (i,))
+ self.samples.append((r, t))
+ def create(self, config):
+ lr = LinearResistance(config, self.samples)
+ return PrinterADCtoTemperature(config, lr)
+
+
+######################################################################
+# Default sensors
+######################################################################
+
AD595 = [
(0., .0027), (10., .101), (20., .200), (25., .250), (30., .300),
(40., .401), (50., .503), (60., .605), (80., .810), (100., 1.015),
@@ -150,6 +194,9 @@ def load_config(config):
pheater.add_sensor(sensor_type, func)
def load_config_prefix(config):
- linear = CustomLinearVoltage(config)
+ if config.get("resistance1", None) is None:
+ custom_sensor = CustomLinearVoltage(config)
+ else:
+ custom_sensor = CustomLinearResistance(config)
pheater = config.get_printer().lookup_object("heater")
- pheater.add_sensor(linear.name, linear.create)
+ pheater.add_sensor(custom_sensor.name, custom_sensor.create)