aboutsummaryrefslogtreecommitdiffstats
path: root/config/sample-macros.cfg
diff options
context:
space:
mode:
Diffstat (limited to 'config/sample-macros.cfg')
-rw-r--r--config/sample-macros.cfg99
1 files changed, 56 insertions, 43 deletions
diff --git a/config/sample-macros.cfg b/config/sample-macros.cfg
index 1f6d84a1..44b8648c 100644
--- a/config/sample-macros.cfg
+++ b/config/sample-macros.cfg
@@ -1,57 +1,70 @@
# This file provides examples of Klipper G-Code macros. The snippets
-# in this file may be copied into the main printer.cfg file.
+# in this file may be copied into the main printer.cfg file and
+# customized.
#
# See the "example.cfg" file for description of common config parameters.
-# M300 : Play tone, Beeper support, as commonly found on usual LCD displays
-# i.e. RepRapDiscount 2004 Smart Controller, RepRapDiscount 12864 Full Graphic
-# This defines a custom I/O pin and a custom GCODE macro
-# Usage: M300 [P<ms>] [S<Hz>] P is the tone duration, S the tone frequency.
-# as it is based on a PWM duty cycle, the frequency won't be pitch perfect.
-#
-#[output_pin BEEPER_pin]
-#pin: ar37
+######################################################################
+# Beeper
+######################################################################
+
+# M300 : Play tone. Beeper support, as commonly found on usual LCD
+# displays (i.e. RepRapDiscount 2004 Smart Controller, RepRapDiscount
+# 12864 Full Graphic). This defines a custom I/O pin and a custom
+# GCODE macro. Usage:
+# M300 [P<ms>] [S<Hz>]
+# P is the tone duration, S the tone frequency.
+# The frequency won't be pitch perfect.
+
+[output_pin BEEPER_pin]
+pin: ar37
# Beeper pin. This parameter must be provided.
# ar37 is the default RAMPS/MKS pin.
-#pwm: True
+pwm: True
# A piezo beeper needs a PWM signal, a DC buzzer doesn't.
-#value: 0
+value: 0
# Silent at power on, set to 1 if active low.
-#shutdown_value: 0
+shutdown_value: 0
# Disable at emergency shutdown (no PWM would be available anyway).
-#cycle_time: 0.001
+cycle_time: 0.001
# PWM frequency : 0.001 = 1ms will give a base tone of 1kHz
-#scale: 1000
+scale: 1000
# PWM parameter will be in the range of (0-1000 Hz).
# Although not pitch perfect.
-#
-#[gcode_macro M300]
-#default_parameter_S=1000
-# Allows for a default 1kHz tone if S is omitted
-#default_parameter_P=100
-# Allows for a default 10ms duration is P is omitted
-#gcode: SET_PIN PIN=BEEPER_pin VALUE={S}
-# G4 P{P}
-# SET_PIN PIN=BEEPER_pin VALUE=0
-# M600: Filament Change. This macro will pause the printer, move
-# the tool to the change position, and retract the filament 50mm.
-# Adjust the retraction settings for your own extruder. After filament
-# has been changed, the print can be resumed from its previous position
-# with the "RESUME" gcode
-#
-#[gcode_macro M600]
-#default_parameter_X: 50
-#default_parameter_Y: 0
-#default_parameter_Z: 10
-#gcode:
-# PAUSE
-# G91
-# G1 E-.8 F2700
-# G1 Z{Z}
-# G90
-# G1 X{X} Y{Y} F3000
-# G91
-# G1 E-50 F1000
-# G90
+[gcode_macro M300]
+default_parameter_S: 1000
+# Use a default 1kHz tone if S is omitted.
+default_parameter_P: 100
+# Use a 10ms duration is P is omitted.
+gcode:
+ SET_PIN PIN=BEEPER_pin VALUE={S}
+ G4 P{P}
+ SET_PIN PIN=BEEPER_pin VALUE=0
+
+
+######################################################################
+# Filament Change
+######################################################################
+
+# M600: Filament Change. This macro will pause the printer, move the
+# tool to the change position, and retract the filament 50mm. Adjust
+# the retraction settings for your own extruder. After filament has
+# been changed, the print can be resumed from its previous position
+# with the "RESUME" gcode.
+
+[gcode_macro M600]
+default_parameter_X: 50
+default_parameter_Y: 0
+default_parameter_Z: 10
+gcode:
+ PAUSE
+ G91
+ G1 E-.8 F2700
+ G1 Z{Z}
+ G90
+ G1 X{X} Y{Y} F3000
+ G91
+ G1 E-50 F1000
+ G90