aboutsummaryrefslogtreecommitdiffstats
path: root/config/example-extras.cfg
diff options
context:
space:
mode:
Diffstat (limited to 'config/example-extras.cfg')
-rw-r--r--config/example-extras.cfg22
1 files changed, 22 insertions, 0 deletions
diff --git a/config/example-extras.cfg b/config/example-extras.cfg
index 33b67178..fa48e780 100644
--- a/config/example-extras.cfg
+++ b/config/example-extras.cfg
@@ -122,6 +122,28 @@
# See the example.cfg for the definition of the above parameters.
+# Heater and temperature sensor verification. Heater verification is
+# automatically enabled for each heater that is configured on the
+# printer. Use verify_heater sections to change the default settings.
+#[verify_heater heater_config_name]
+#heating_gain: 2
+# The minimum temperature (in Celsius) that the heater must increase
+# by when approaching a new target temperature. The default is 2.
+#check_gain_time:
+# The amount of time (in seconds) that the heating_gain must be met
+# in before an error is raised. The default is 20 seconds for
+# extruders and 60 seconds for heater_bed.
+#hysteresis: 4
+# The difference between the target temperature and the current
+# temperature for the heater to be considered within range of the
+# target temperature. The default is 4.
+#check_time: 10
+# The amount of time (in seconds) a heater that has reached the
+# target temperature (as defined by the hysteresis field) may fall
+# outside the target temperature range before an error is
+# raised. The default is 10.
+
+
# Multi-stepper axes. On a cartesian style printer, the stepper
# controlling a given axis may have additional config blocks defining
# steppers that should be stepped in concert with the primary