aboutsummaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
-rw-r--r--klippy/extras/spi_temperature.py61
1 files changed, 35 insertions, 26 deletions
diff --git a/klippy/extras/spi_temperature.py b/klippy/extras/spi_temperature.py
index be8cc11e..29df3536 100644
--- a/klippy/extras/spi_temperature.py
+++ b/klippy/extras/spi_temperature.py
@@ -51,12 +51,15 @@ class SensorBase:
self.oid, clock, self._report_clock,
self.min_sample_value, self.max_sample_value), is_init=True)
def _handle_spi_response(self, params):
- temp = self.calc_temp(params['value'], params['fault'])
+ if params['fault']:
+ self.handle_fault(params['value'], params['fault'])
+ return
+ temp = self.calc_temp(params['value'])
next_clock = self.mcu.clock32_to_clock64(params['next_clock'])
last_read_clock = next_clock - self._report_clock
last_read_time = self.mcu.clock_to_print_time(last_read_clock)
self._callback(last_read_time, temp)
- def fault(self, msg):
+ def report_fault(self, msg):
self.printer.invoke_async_shutdown(msg)
@@ -120,23 +123,24 @@ class MAX31856(SensorBase):
def __init__(self, config):
SensorBase.__init__(self, config, "MAX31856",
self.build_spi_init(config))
- def calc_temp(self, adc, fault):
+ def handle_fault(self, adc, fault):
if fault & MAX31856_FAULT_CJRANGE:
- self.fault("Max31856: Cold Junction Range Fault")
+ self.report_fault("Max31856: Cold Junction Range Fault")
if fault & MAX31856_FAULT_TCRANGE:
- self.fault("Max31856: Thermocouple Range Fault")
+ self.report_fault("Max31856: Thermocouple Range Fault")
if fault & MAX31856_FAULT_CJHIGH:
- self.fault("Max31856: Cold Junction High Fault")
+ self.report_fault("Max31856: Cold Junction High Fault")
if fault & MAX31856_FAULT_CJLOW:
- self.fault("Max31856: Cold Junction Low Fault")
+ self.report_fault("Max31856: Cold Junction Low Fault")
if fault & MAX31856_FAULT_TCHIGH:
- self.fault("Max31856: Thermocouple High Fault")
+ self.report_fault("Max31856: Thermocouple High Fault")
if fault & MAX31856_FAULT_TCLOW:
- self.fault("Max31856: Thermocouple Low Fault")
+ self.report_fault("Max31856: Thermocouple Low Fault")
if fault & MAX31856_FAULT_OVUV:
- self.fault("Max31856: Over/Under Voltage Fault")
+ self.report_fault("Max31856: Over/Under Voltage Fault")
if fault & MAX31856_FAULT_OPEN:
- self.fault("Max31856: Thermocouple Open Fault")
+ self.report_fault("Max31856: Thermocouple Open Fault")
+ def calc_temp(self, adc):
adc = adc >> MAX31856_SCALE
# Fix sign bit:
if adc & 0x40000:
@@ -192,13 +196,14 @@ MAX31855_MULT = 0.25
class MAX31855(SensorBase):
def __init__(self, config):
SensorBase.__init__(self, config, "MAX31855", spi_mode=0)
- def calc_temp(self, adc, fault):
+ def handle_fault(self, adc, fault):
if fault & 0x1:
- self.fault("MAX31855 : Open Circuit")
+ self.report_fault("MAX31855 : Open Circuit")
if fault & 0x2:
- self.fault("MAX31855 : Short to GND")
+ self.report_fault("MAX31855 : Short to GND")
if fault & 0x4:
- self.fault("MAX31855 : Short to Vcc")
+ self.report_fault("MAX31855 : Short to Vcc")
+ def calc_temp(self, adc):
adc = adc >> MAX31855_SCALE
# Fix sign bit:
if adc & 0x2000:
@@ -221,11 +226,12 @@ MAX6675_MULT = 0.25
class MAX6675(SensorBase):
def __init__(self, config):
SensorBase.__init__(self, config, "MAX6675", spi_mode=0)
- def calc_temp(self, adc, fault):
+ def handle_fault(self, adc, fault):
if fault & 0x02:
- self.fault("Max6675 : Device ID error")
+ self.report_fault("Max6675 : Device ID error")
if fault & 0x04:
- self.fault("Max6675 : Thermocouple Open Fault")
+ self.report_fault("Max6675 : Thermocouple Open Fault")
+ def calc_temp(self, adc):
adc = adc >> MAX6675_SCALE
# Fix sign bit:
if adc & 0x2000:
@@ -279,22 +285,25 @@ class MAX31865(SensorBase):
self.adc_to_resist_div_nominal = adc_to_resist / rtd_nominal_r
SensorBase.__init__(self, config, "MAX31865",
self.build_spi_init(config))
- def calc_temp(self, adc, fault):
+ def handle_fault(self, adc, fault):
if fault & 0x80:
- self.fault("Max31865 RTD input is disconnected")
+ self.report_fault("Max31865 RTD input is disconnected")
if fault & 0x40:
- self.fault("Max31865 RTD input is shorted")
+ self.report_fault("Max31865 RTD input is shorted")
if fault & 0x20:
- self.fault(
+ self.report_fault(
"Max31865 VREF- is greater than 0.85 * VBIAS, FORCE- open")
if fault & 0x10:
- self.fault("Max31865 VREF- is less than 0.85 * VBIAS, FORCE- open")
+ self.report_fault(
+ "Max31865 VREF- is less than 0.85 * VBIAS, FORCE- open")
if fault & 0x08:
- self.fault("Max31865 VRTD- is less than 0.85 * VBIAS, FORCE- open")
+ self.report_fault(
+ "Max31865 VRTD- is less than 0.85 * VBIAS, FORCE- open")
if fault & 0x04:
- self.fault("Max31865 Overvoltage or undervoltage fault")
+ self.report_fault("Max31865 Overvoltage or undervoltage fault")
if not fault & 0xfc:
- self.fault("Max31865 Unspecified error")
+ self.report_fault("Max31865 Unspecified error")
+ def calc_temp(self, adc):
adc = adc >> 1 # remove fault bit
R_div_nominal = adc * self.adc_to_resist_div_nominal
# Resistance (relative to rtd_nominal_r) is calculated using: