aboutsummaryrefslogtreecommitdiffstats
path: root/klippy/extras/mpu9250.py
diff options
context:
space:
mode:
authorKevin O'Connor <kevin@koconnor.net>2023-12-16 22:00:23 -0500
committerKevin O'Connor <kevin@koconnor.net>2023-12-26 11:47:21 -0500
commit43ce7c0b9ad4f30277c10b086b86a0937dbfebbc (patch)
tree8b18618378709bc580bc00048589581f57ceeb46 /klippy/extras/mpu9250.py
parentd6a4669ce092496bb675a28732aa5f6a11360caf (diff)
downloadkutter-43ce7c0b9ad4f30277c10b086b86a0937dbfebbc.tar.gz
kutter-43ce7c0b9ad4f30277c10b086b86a0937dbfebbc.tar.xz
kutter-43ce7c0b9ad4f30277c10b086b86a0937dbfebbc.zip
adxl345: No need to implement is_measuring()
The APIDumpHelper class already ensures that the start/stop callbacks will only be called when needed. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'klippy/extras/mpu9250.py')
-rw-r--r--klippy/extras/mpu9250.py9
1 files changed, 0 insertions, 9 deletions
diff --git a/klippy/extras/mpu9250.py b/klippy/extras/mpu9250.py
index 6ca300cd..d1ef9954 100644
--- a/klippy/extras/mpu9250.py
+++ b/klippy/extras/mpu9250.py
@@ -59,7 +59,6 @@ class MPU9250:
def __init__(self, config):
self.printer = config.get_printer()
adxl345.AccelCommandHelper(config, self)
- self.query_rate = 0
am = {'x': (0, SCALE), 'y': (1, SCALE), 'z': (2, SCALE),
'-x': (0, -SCALE), '-y': (1, -SCALE), '-z': (2, -SCALE)}
axes_map = config.getlist('axes_map', ('x','y','z'), count=3)
@@ -116,8 +115,6 @@ class MPU9250:
self.i2c.i2c_write([reg, val & 0xFF], minclock=minclock)
# Measurement collection
- def is_measuring(self):
- return self.query_rate > 0
def _extract_samples(self, raw_samples):
# Load variables to optimize inner loop below
(x_pos, x_scale), (y_pos, y_scale), (z_pos, z_scale) = self.axes_map
@@ -157,8 +154,6 @@ class MPU9250:
minclock=minclock)
self.clock_updater.update_clock(params)
def _start_measurements(self):
- if self.is_measuring():
- return
# In case of miswiring, testing MPU9250 device ID prevents treating
# noise or wrong signal as a correctly initialized device
dev_id = self.read_reg(REG_DEVID)
@@ -185,7 +180,6 @@ class MPU9250:
print_time = self.mcu.estimated_print_time(systime) + MIN_MSG_TIME
reqclock = self.mcu.print_time_to_clock(print_time)
rest_ticks = self.mcu.seconds_to_clock(4. / self.data_rate)
- self.query_rate = self.data_rate
self.query_mpu9250_cmd.send([self.oid, reqclock, rest_ticks],
reqclock=reqclock)
logging.info("MPU9250 starting '%s' measurements", self.name)
@@ -195,11 +189,8 @@ class MPU9250:
self.clock_updater.clear_duration_filter()
self.last_error_count = 0
def _finish_measurements(self):
- if not self.is_measuring():
- return
# Halt bulk reading
params = self.query_mpu9250_end_cmd.send([self.oid, 0, 0])
- self.query_rate = 0
self.bulk_queue.clear_samples()
logging.info("MPU9250 finished '%s' measurements", self.name)
self.set_reg(REG_PWR_MGMT_1, SET_PWR_MGMT_1_SLEEP)