docs: Fix nested list in Measuring_Resonances (#6157)
Signed-off-by: Matthew Swabey <matthew@swabey.org>
Diffstat (limited to 'docs')
-rw-r--r--docs/Measuring_Resonances.md20
1 files changed, 10 insertions, 10 deletions
diff --git a/docs/Measuring_Resonances.md b/docs/Measuring_Resonances.md
index 1ab21eed..0897628f 100644
--- a/docs/Measuring_Resonances.md
+++ b/docs/Measuring_Resonances.md
@@ -36,16 +36,16 @@ An ethernet cable with shielded twisted pairs (cat5e or better) is recommended
for signal integrity over a long distance. If you still experience signal
integrity issues (SPI/I2C errors):
- * Double check the wiring with a digital multimeter for:
- * Correct connections when turned off (continuity)
- * Correct power and ground voltages
- * I2C only:
- * Check the SCL and SDA lines' resistances to 3.3V are in the range of 900
- ohms to 1.8K
- * For full technical details consult [chapter 7 of the I2C-bus specification
- and user manual UM10204](https://www.pololu.com/file/0J435/UM10204.pdf)
- for *fast-mode*
- * Shorten the cable
+- Double check the wiring with a digital multimeter for:
+ - Correct connections when turned off (continuity)
+ - Correct power and ground voltages
+- I2C only:
+ - Check the SCL and SDA lines' resistances to 3.3V are in the range of 900
+ ohms to 1.8K
+ - For full technical details consult [chapter 7 of the I2C-bus specification
+ and user manual UM10204](https://www.pololu.com/file/0J435/UM10204.pdf)
+ for *fast-mode*
+- Shorten the cable
Connect ethernet cable shielding only to the MCU board/Pi ground.