aboutsummaryrefslogtreecommitdiffstats
path: root/docs/Rotation_Distance.md
diff options
context:
space:
mode:
authorKevin O'Connor <kevin@koconnor.net>2021-08-25 12:03:44 -0400
committerKevin O'Connor <kevin@koconnor.net>2021-08-25 12:07:21 -0400
commit25e493ef7553f064d7ce4706cac7df3e8a78bf23 (patch)
tree840c369a8e61e28bba9b5b7799da799b449b718c /docs/Rotation_Distance.md
parent84ac5b0146cbcec46419d4636b949f144992072e (diff)
downloadkutter-25e493ef7553f064d7ce4706cac7df3e8a78bf23.tar.gz
kutter-25e493ef7553f064d7ce4706cac7df3e8a78bf23.tar.xz
kutter-25e493ef7553f064d7ce4706cac7df3e8a78bf23.zip
docs: Note importance of slow extrude rate in Rotation_Distance.md
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'docs/Rotation_Distance.md')
-rw-r--r--docs/Rotation_Distance.md6
1 files changed, 5 insertions, 1 deletions
diff --git a/docs/Rotation_Distance.md b/docs/Rotation_Distance.md
index 0d7c6c9b..c2411a8a 100644
--- a/docs/Rotation_Distance.md
+++ b/docs/Rotation_Distance.md
@@ -62,7 +62,11 @@ Then use the following procedure to "measure and trim":
3. Extrude 50mm of filament with the following command sequence: `G91`
followed by `G1 E50 F60`. Note 50mm as
`<requested_extrude_distance>`. Wait for the extruder to finish the
- move (it will take about 50 seconds).
+ move (it will take about 50 seconds). It is important to use the
+ slow extrusion rate for this test as a faster rate can cause high
+ pressure in the extruder which will skew the results. (Do not use
+ the "extrude button" on graphical front-ends for this test as they
+ extrude at a fast rate.)
4. Use the digital calipers to measure the new distance between the
extruder body and the mark on the filament. Note this as
`<subsequent_mark_distance>`. Then calculate: