docs: Note pressure_advance over 0.20 is unlikely to improve quality
Update the pressure advance tuning document to note that 0.20 is likely the ceiling of a useful pressure advance setting. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'docs/Pressure_Advance.md')
-rw-r--r--docs/Pressure_Advance.md5
1 files changed, 4 insertions, 1 deletions
diff --git a/docs/Pressure_Advance.md b/docs/Pressure_Advance.md
index 3d7731e8..9afee00b 100644
--- a/docs/Pressure_Advance.md
+++ b/docs/Pressure_Advance.md
@@ -63,7 +63,10 @@ in good quality corners:
![corner-good](img/corner-good.jpg)
Typical pressure_advance values are between 0.05 and 0.20 (the high
-end usually only with bowden extruders).
+end usually only with bowden extruders). If there is no significant
+improvement seen after increasing pressure_advance to 0.20, then
+pressure advance is unlikely to improve the quality of prints. Return
+to a default configuration with pressure_advance disabled.
It is not unusual for one corner of the test print to be consistently
different than the other three corners. This typically occurs when the