aboutsummaryrefslogtreecommitdiffstats
path: root/docs/Measuring_Resonances.md
diff options
context:
space:
mode:
authorYifei Ding <dingyifeiair@gmail.com>2021-10-23 11:21:46 -0700
committerKevinOConnor <kevin@koconnor.net>2021-11-19 10:25:06 -0500
commitee04a6340a028b84ea5cc1db278b38869ab4b9c7 (patch)
treee552b8688328c80001c1c3e17368b7e0cdc8b100 /docs/Measuring_Resonances.md
parent46381e03a4e27f5905aafafeabab077c9bdf7f33 (diff)
downloadkutter-ee04a6340a028b84ea5cc1db278b38869ab4b9c7.tar.gz
kutter-ee04a6340a028b84ea5cc1db278b38869ab4b9c7.tar.xz
kutter-ee04a6340a028b84ea5cc1db278b38869ab4b9c7.zip
docs: Align Lists
Signed-off-by: Yifei Ding <yifeiding@protonmail.com>
Diffstat (limited to 'docs/Measuring_Resonances.md')
-rw-r--r--docs/Measuring_Resonances.md46
1 files changed, 23 insertions, 23 deletions
diff --git a/docs/Measuring_Resonances.md b/docs/Measuring_Resonances.md
index 1487cda5..e940713a 100644
--- a/docs/Measuring_Resonances.md
+++ b/docs/Measuring_Resonances.md
@@ -483,18 +483,18 @@ The data can be processed later by the following scripts:
of them accept one or several raw csv files as the input depending on the
mode. The graph_accelerometer.py script supports several modes of operation:
- * plotting raw accelerometer data (use `-r` parameter), only 1 input is
- supported;
- * plotting a frequency response (no extra parameters required), if multiple
- inputs are specified, the average frequency response is computed;
- * comparison of the frequency response between several inputs (use `-c`
- parameter); you can additionally specify which accelerometer axis to
+* plotting raw accelerometer data (use `-r` parameter), only 1 input is
+ supported;
+* plotting a frequency response (no extra parameters required), if multiple
+ inputs are specified, the average frequency response is computed;
+* comparison of the frequency response between several inputs (use `-c`
+ parameter); you can additionally specify which accelerometer axis to
consider via `-a x`, `-a y` or `-a z` parameter (if none specified,
the sum of vibrations for all axes is used);
- * plotting the spectrogram (use `-s` parameter), only 1 input is supported;
- you can additionally specify which accelerometer axis to consider via
- `-a x`, `-a y` or `-a z` parameter (if none specified, the sum of vibrations
- for all axes is used).
+* plotting the spectrogram (use `-s` parameter), only 1 input is supported;
+ you can additionally specify which accelerometer axis to consider via
+ `-a x`, `-a y` or `-a z` parameter (if none specified, the sum of vibrations
+ for all axes is used).
Note that graph_accelerometer.py script supports only the raw_data\*.csv files
and not resonances\*.csv or calibration_data\*.csv files.
@@ -515,16 +515,16 @@ the CSV file if `-c output.csv` parameter is specified.
Providing several inputs to shaper_calibrate.py script can be useful if running
some advanced tuning of the input shapers, for example:
- * Running `TEST_RESONANCES AXIS=X OUTPUT=raw_data` (and `Y` axis) for a single
- axis twice on a bed slinger printer with the accelerometer attached to the
- toolhead the first time, and the accelerometer attached to the bed the
- second time in order to detect axes cross-resonances and attempt to cancel
- them with input shapers.
- * Running `TEST_RESONANCES AXIS=Y OUTPUT=raw_data` twice on a bed slinger with
- a glass bed and a magnetic surfaces (which is lighter) to find the input
- shaper parameters that work well for any print surface configuration.
- * Combining the resonance data from multiple test points.
- * Combining the resonance data from 2 axis (e.g. on a bed slinger printer
- to configure X-axis input_shaper from both X and Y axes resonances to
- cancel vibrations of the *bed* in case the nozzle 'catches' a print when
- moving in X axis direction).
+* Running `TEST_RESONANCES AXIS=X OUTPUT=raw_data` (and `Y` axis) for a single
+ axis twice on a bed slinger printer with the accelerometer attached to the
+ toolhead the first time, and the accelerometer attached to the bed the
+ second time in order to detect axes cross-resonances and attempt to cancel
+ them with input shapers.
+* Running `TEST_RESONANCES AXIS=Y OUTPUT=raw_data` twice on a bed slinger with
+ a glass bed and a magnetic surfaces (which is lighter) to find the input
+ shaper parameters that work well for any print surface configuration.
+* Combining the resonance data from multiple test points.
+* Combining the resonance data from 2 axis (e.g. on a bed slinger printer
+ to configure X-axis input_shaper from both X and Y axes resonances to
+ cancel vibrations of the *bed* in case the nozzle 'catches' a print when
+ moving in X axis direction).