aboutsummaryrefslogtreecommitdiffstats
path: root/docs/G-Codes.md
diff options
context:
space:
mode:
authorKevin O'Connor <kevin@koconnor.net>2019-02-09 22:54:24 -0500
committerKevin O'Connor <kevin@koconnor.net>2019-02-12 13:20:32 -0500
commitb0b9fc6f4a8a0cf16166b1ea2f29fb4747873d30 (patch)
tree64652fe1cbeae97d0e666c582ad0407de5a2959c /docs/G-Codes.md
parent35ea4a137d15c04f2997315002928dd049bb0536 (diff)
downloadkutter-b0b9fc6f4a8a0cf16166b1ea2f29fb4747873d30.tar.gz
kutter-b0b9fc6f4a8a0cf16166b1ea2f29fb4747873d30.tar.xz
kutter-b0b9fc6f4a8a0cf16166b1ea2f29fb4747873d30.zip
probe: Use manual_probe helper when performing manual probes
Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'docs/G-Codes.md')
-rw-r--r--docs/G-Codes.md24
1 files changed, 12 insertions, 12 deletions
diff --git a/docs/G-Codes.md b/docs/G-Codes.md
index 58c7a75d..38b90a13 100644
--- a/docs/G-Codes.md
+++ b/docs/G-Codes.md
@@ -190,10 +190,10 @@ The following commands are available when the "delta_calibrate" config
section is enabled:
- `DELTA_CALIBRATE [METHOD=manual]`: This command will probe seven
points on the bed and recommend updated endstop positions, tower
- angles, and radius.
- - `NEXT`: If manual bed probing is enabled, then one can use this
- command to move to the next probing point during a DELTA_CALIBRATE
- operation.
+ angles, and radius. If METHOD=manual is specified then the manual
+ probing tool is activated - see the MANUAL_PROBE command above for
+ details on the additional commands available while this tool is
+ active.
- `DELTA_ANALYZE`: This command is used during enhanced delta
calibration. See [Delta Calibrate](Delta_Calibrate.md) for details.
@@ -203,10 +203,10 @@ The following commands are available when the "bed_tilt" config
section is enabled:
- `BED_TILT_CALIBRATE [METHOD=manual]`: This command will probe the
points specified in the config and then recommend updated x and y
- tilt adjustments.
- - `NEXT`: If manual bed probing is enabled, then one can use this
- command to move to the next probing point during a
- BED_TILT_CALIBRATE operation.
+ tilt adjustments. If METHOD=manual is specified then the manual
+ probing tool is activated - see the MANUAL_PROBE command above for
+ details on the additional commands available while this tool is
+ active.
## Mesh Bed Leveling
@@ -215,10 +215,10 @@ section is enabled:
- `BED_MESH_CALIBRATE [METHOD=manual]`: This command probes the bed
using generated points specified by the parameters in the
config. After probing, a mesh is generated and z-movement is
- adjusted according to the mesh.
- - `NEXT`: If manual bed probing is enabled, then one can use this
- command to move to the next probing point during a
- BED_MESH_CALIBRATE operation.
+ adjusted according to the mesh. If METHOD=manual is specified then
+ the manual probing tool is activated - see the MANUAL_PROBE command
+ above for details on the additional commands available while this
+ tool is active.
- `BED_MESH_OUTPUT`: This command outputs the current probed z values
and current mesh values to the terminal.
- `BED_MESH_MAP`: This command probes the bed in a similar fashion