temperature_sensors: Deprecate "NTC 100K beta 3950" thermistor
It seems the common "beta 3950" thermistors generally follow a temperature table defined by the new "Generic 3950" definition. Using a table that actually follows the "beta 3950" temperature curve is generally less accurate. Deprecate the existing "NTC 100K beta 3950" definition to avoid this common issue. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'docs/Config_Changes.md')
-rw-r--r--docs/Config_Changes.md7
1 files changed, 7 insertions, 0 deletions
diff --git a/docs/Config_Changes.md b/docs/Config_Changes.md
index 828094b0..13c4da5e 100644
--- a/docs/Config_Changes.md
+++ b/docs/Config_Changes.md
@@ -8,6 +8,13 @@ All dates in this document are approximate.
## Changes
+20211110: The "NTC 100K beta 3950" temperature sensor is deprecated.
+This sensor will be removed in the near future. Most users will find
+the "Generic 3950" temperature sensor more accurate. To continue to
+use the older (typically less accurate) definition, define a custom
+[thermistor](Config_Reference.md#thermistor) with `temperature1: 25`,
+`resistance1: 100000`, and `beta: 3950`.
+
20211104: The "step pulse duration" option in "make menuconfig" has
been removed. A new `step_pulse_duration` setting in the
[stepper config section](Config_Reference.md#stepper) should be set