resonance_tester: Resonance testing and input shaper auto-calibration (#3381)
Signed-off-by: Dmitry Butyugin <dmbutyugin@google.com>
Diffstat (limited to 'config')
-rw-r--r-- | config/example-extras.cfg | 44 |
1 files changed, 44 insertions, 0 deletions
diff --git a/config/example-extras.cfg b/config/example-extras.cfg index a99e9dc4..2f2bc4cf 100644 --- a/config/example-extras.cfg +++ b/config/example-extras.cfg @@ -569,6 +569,11 @@ # example, one could set this to "y,x,z" to swap the x and y axes. # It is also possible to negate an axis if the accelerometer # direction is reversed (eg, "x,z,-y"). The default is "x,y,z". +#rate: 3200 +# Output data rate for ADXL345. ADXL345 supports the following data rates: +# 3200, 1600, 800, 400, 200, 100, 50, and 25. Note that it is not recommended +# to change this rate from the default 3200, and rates below 800 will +# considerably affect the quality of resonance measurements. #cs_pin: # The SPI enable pin for the sensor. This parameter must be # provided. @@ -582,6 +587,45 @@ # These optional parameters allow one to customize the SPI settings # used to communicate with the chip. +# Support for resonance testing and automatic input shaper calibration. +# In order to use most of the functionality of this module, additional +# software dependencies must be installed; refer to docs/Measuring_Resonances.md +# for more information. +#[resonance_tester] +#probe_points: +# A list of X,Y,Z coordinates of points (one point per line) to test +# resonances at. At least one point is required. Make sure that all +# points with some safety margin in XY plane (~a few centimeters) are +# reachable by the toolhead. +#accel_chip: +# A name of the accelerometer chip to use for measurements. If adxl345 chip +# was defined without an explicit name, this parameter can simply reference +# it as "accel_chip: adxl345", otherwise an explicit name must be supplied +# as well, e.g. "accel_chip: adxl345 my_chip_name". Either this, or the next +# two parameters must be set. +#accel_chip_x: +#accel_chip_y: +# Names of the accelerometer chips to use for measurements for each of the +# axis. Can be useful, for instance, on bed slinger printer, if two separate +# accelerometers are mounted on the bed (for Y axis) and on the toolhead (for +# X axis). These parameters have the same format as 'accel_chip' parameter. +# Only 'accel_chip' or these two parameters must be provided. +#min_freq: 5 +# Minimum frequency to test for resonances. The default is 5 Hz. +#max_freq: 120 +# Maximum frequency to test for resonances. The default is 120 Hz. +#accel_per_hz: 75 +# This parameter is used to determine which acceleration to use to test a +# specific frequency: accel = accel_per_hz * freq. Higher the value, the +# higher is the energy of the oscillations. Can be set to a lower than the +# default value if the resonances get too strong on the printer. However, +# lower values make measurements of high-frequency resonances less precise. +# The default value is 75 (mm/sec). +#hz_per_sec: 1 +# Determines the speed of the test. When testing all frequencies in range +# [min_freq, max_freq], each second the frequency increases by hz_per_sec. +# Small values make the test slow, and the large values will decrease the +# precision of the test. The default value is 1.0 (Hz/sec == sec^-2). ###################################################################### # Config file helpers |