temperature_sensors: Deprecate "NTC 100K beta 3950" thermistor
It seems the common "beta 3950" thermistors generally follow a temperature table defined by the new "Generic 3950" definition. Using a table that actually follows the "beta 3950" temperature curve is generally less accurate. Deprecate the existing "NTC 100K beta 3950" definition to avoid this common issue. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'config/printer-mtw-create-2015.cfg')
-rw-r--r--config/printer-mtw-create-2015.cfg2
1 files changed, 1 insertions, 1 deletions
diff --git a/config/printer-mtw-create-2015.cfg b/config/printer-mtw-create-2015.cfg
index cae0524e..4194fd23 100644
--- a/config/printer-mtw-create-2015.cfg
+++ b/config/printer-mtw-create-2015.cfg
@@ -79,7 +79,7 @@ max_temp: 275
[heater_bed]
heater_pin: PE5
-sensor_type: NTC 100K beta 3950
+sensor_type: Generic 3950
sensor_pin: PF2
control: watermark
min_temp: 0