aboutsummaryrefslogtreecommitdiffstats
path: root/config/printer-creality-cr6se-2021.cfg
diff options
context:
space:
mode:
authorStéphane Lepin <stephane.lepin@gmail.com>2024-05-11 02:18:38 +0200
committerKevinOConnor <kevin@koconnor.net>2024-05-12 20:08:30 -0400
commit79930ed99a1fc284f41af5755908aa1fab948ce1 (patch)
tree3e35a234fc052394d589b0f7a619e3dce73432ef /config/printer-creality-cr6se-2021.cfg
parent434770eaf9d382cccba203a3475ace2dc0653d7b (diff)
downloadkutter-79930ed99a1fc284f41af5755908aa1fab948ce1.tar.gz
kutter-79930ed99a1fc284f41af5755908aa1fab948ce1.tar.xz
kutter-79930ed99a1fc284f41af5755908aa1fab948ce1.zip
config: Add safe_z_home section for Creality CR-6 SE
The Creality CR-6 SE has a strain gauge on its hotend used for z-probing and homing. Currently, running G28 to home all axes puts the hotend just outside of the print bed and thus assumes a wrong homing point for the Z axis. This change aims to address this issue by setting a safe Z-homing point (in the middle of the print bed) into the Creality CR-6 SE 2020 and 2021-revision config files. Signed-off-by: Stéphane Lepin <stephane.lepin@gmail.com>
Diffstat (limited to 'config/printer-creality-cr6se-2021.cfg')
-rw-r--r--config/printer-creality-cr6se-2021.cfg4
1 files changed, 4 insertions, 0 deletions
diff --git a/config/printer-creality-cr6se-2021.cfg b/config/printer-creality-cr6se-2021.cfg
index 12c17120..932a9263 100644
--- a/config/printer-creality-cr6se-2021.cfg
+++ b/config/printer-creality-cr6se-2021.cfg
@@ -98,6 +98,10 @@ z_offset: 0.0
speed: 2.0
samples: 5
+[safe_z_home]
+home_xy_position: 117, 117
+z_hop: 10
+
[filament_switch_sensor filament_sensor]
pause_on_runout: true
switch_pin: ^!PA7