config: Move some sections around in example-extras.cfg
Move the quad_gantry_level description closer to z_tilt section. Move the force_move section closer to the homing_override section. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
Diffstat (limited to 'config/example-extras.cfg')
-rw-r--r--config/example-extras.cfg102
1 files changed, 53 insertions, 49 deletions
diff --git a/config/example-extras.cfg b/config/example-extras.cfg
index 1ec4a1cb..9eed2993 100644
--- a/config/example-extras.cfg
+++ b/config/example-extras.cfg
@@ -174,6 +174,48 @@
# The distance (in mm) to retract between each sample if
# sampling more than once. Default is 2mm.
+
+# Moving gantry leveling using 4 independently controlled Z motors.
+# Corrects hyperbolic parabola effects (potato chip) on moving gantry
+# which is more flexible.
+# WARNING: Using this on a moving bed may lead to undesirable results.
+# If this section is present then a QUAD_GANTRY_LEVEL extended G-Code
+# command becomes available. This routine assumes the following Z motor
+# configuration:
+# ----------------
+# |Z1 Z2|
+# | --------- |
+# | | | |
+# | | | |
+# | x-------- |
+# |Z Z3|
+# ----------------
+# Where x is the (0,0) point on the bed
+#[quad_gantry_level]
+#gantry_corners:
+# A newline separated list of X,Y coordinates describing the
+# two opposing corners of the gantry. The first entry corresponds to
+# Z, the second to Z2.
+# This parameter must be provided.
+#points:
+# A newline separated list of four X,Y points that should be probed
+# during a QUAD_GANTRY_LEVEL command.
+# Order of the locations is important, and should correspond to Z,Z1
+# Z2, and Z3 location in order.
+# This parameter must be provided.
+# For maximum accuracy, ensure your probe offsets are configured.
+#speed: 50
+# The speed (in mm/s) of non-probing moves during the calibration.
+# The default is 50.
+#horizontal_move_z: 5
+# The height (in mm) that the head should be commanded to move to
+# just prior to starting a probe operation. The default is 5
+#samples: 1
+# Number of probe samples per point. The defaut is 1
+#sample_retract_dist: 2.0
+# Distance in mm to retract the probe between samples. Default is 2.
+
+
# In a multi-extruder printer add an additional extruder section for
# each additional extruder. The additional extruder sections should be
# named "extruder1", "extruder2", "extruder3", and so on. See the
@@ -608,6 +650,7 @@
# to an appropriate sensitivity value.) The default is to not enable
# sensorless homing.
+
# Configure a TMC2208 (or TMC2224) stepper motor driver via single
# wire UART. To use this feature, define a config section with a
# "tmc2208" prefix followed by the name of the corresponding stepper
@@ -770,6 +813,15 @@
# axis. The default is to not force a position for an axis.
+# Support manually moving stepper motors for diagnostic purposes.
+# Note, using this feature may place the printer in an invalid state -
+# see docs/G-Codes.md for important details.
+#[force_move]
+#enable_force_move: False
+# Set to true to enable FORCE_MOVE and SET_KINEMATIC_POSITION
+# extended G-Code commands. The default is false.
+
+
# A virtual sdcard may be useful if the host machine is not fast
# enough to run OctoPrint well. It allows the Klipper host software to
# directly print gcode files stored in a directory on the host using
@@ -836,6 +888,7 @@
# The pin connected to 'kill' button. This button will call
# emergency stop.
+
# Custom thermistors (one may define any number of sections with a
# "thermistor" prefix). A custom thermistor may be used in the
# sensor_type field of a heater config section. (For example, if one
@@ -912,15 +965,6 @@
# name in the above list.
-# Support manually moving stepper motors for diagnostic purposes.
-# Note, using this feature may place the printer in an invalid state -
-# see docs/G-Codes.md for important details.
-#[force_move]
-#enable_force_move: False
-# Set to true to enable FORCE_MOVE and SET_KINEMATIC_POSITION
-# extended G-Code commands. The default is false.
-
-
# G-Code macros (one may define any number of sections with a
# "gcode_macro" prefix).
#[gcode_macro my_cmd]
@@ -933,43 +977,3 @@
# Replicape support - see the generic-replicape.cfg file for further
# details.
#[replicape]
-
-# Moving gantry leveling using 4 independently controlled Z motors.
-# Corrects hyperbolic parabola effects (potato chip) on moving gantry
-# which is more flexible.
-# WARNING: Using this on a moving bed may lead to undesirable results.
-# If this section is present then a QUAD_GANTRY_LEVEL extended G-Code
-# command becomes available. This routine assumes the following Z motor
-# configuration:
-# ----------------
-# |Z1 Z2|
-# | --------- |
-# | | | |
-# | | | |
-# | x-------- |
-# |Z Z3|
-# ----------------
-# Where x is the (0,0) point on the bed
-#[quad_gantry_level]
-#gantry_corners:
-# A newline separated list of X,Y coordinates describing the
-# two opposing corners of the gantry. The first entry corresponds to
-# Z, the second to Z2.
-# This parameter must be provided.
-#points:
-# A newline separated list of four X,Y points that should be probed
-# during a QUAD_GANTRY_LEVEL command.
-# Order of the locations is important, and should correspond to Z,Z1
-# Z2, and Z3 location in order.
-# This parameter must be provided.
-# For maximum accuracy, ensure your probe offsets are configured.
-#speed: 50
-# The speed (in mm/s) of non-probing moves during the calibration.
-# The default is 50.
-#horizontal_move_z: 5
-# The height (in mm) that the head should be commanded to move to
-# just prior to starting a probe operation. The default is 5
-#samples: 1
-# Number of probe samples per point. The defaut is 1
-#sample_retract_dist: 2.0
-# Distance in mm to retract the probe between samples. Default is 2.