From 879c45db191251af2a00e75bf6ba89ab876c2fad Mon Sep 17 00:00:00 2001 From: Kevin O'Connor Date: Mon, 28 May 2018 11:44:42 -0400 Subject: mcu: Do not automatically restart MCU with new config if it is shutdown Normally, the MCU is restarted on a config change. However, that should not be done automatically if the MCU is in a shutdown state. Signed-off-by: Kevin O'Connor --- src/basecmd.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) (limited to 'src/basecmd.c') diff --git a/src/basecmd.c b/src/basecmd.c index 08dc6ec2..8ce7a27c 100644 --- a/src/basecmd.c +++ b/src/basecmd.c @@ -201,8 +201,8 @@ static uint32_t config_crc; void command_get_config(uint32_t *args) { - sendf("config is_config=%c crc=%u move_count=%hu" - , is_finalized(), config_crc, move_count); + sendf("config is_config=%c crc=%u move_count=%hu is_shutdown=%c" + , is_finalized(), config_crc, move_count, sched_is_shutdown()); } DECL_COMMAND_FLAGS(command_get_config, HF_IN_SHUTDOWN, "get_config"); -- cgit v1.2.3-70-g09d2