From cf6c5e6f180587924f9c46bb1db141089823da3a Mon Sep 17 00:00:00 2001 From: Kevin O'Connor Date: Mon, 25 Feb 2019 20:12:32 -0500 Subject: gcode: A set temperature request should use the heater name, not the gcode id When setting a temperature, lookup the heater via self.heaters.lookup_heater() and do not use the gcode ids. This fixes temperature setting when multiple extruders share the same heater. Signed-off-by: Kevin O'Connor --- klippy/heater.py | 9 ++------- 1 file changed, 2 insertions(+), 7 deletions(-) (limited to 'klippy/heater.py') diff --git a/klippy/heater.py b/klippy/heater.py index 90e1129b..7fb89563 100644 --- a/klippy/heater.py +++ b/klippy/heater.py @@ -265,18 +265,13 @@ class PrinterHeaters: raise self.printer.config_error("Unknown temperature sensor '%s'" % ( sensor_type,)) return self.sensors[sensor_type](config) + def get_all_heaters(self): + return self.heaters.values() cmd_TURN_OFF_HEATERS_help = "Turn off all heaters" def cmd_TURN_OFF_HEATERS(self, params): print_time = self.printer.lookup_object('toolhead').get_last_move_time() for heater in self.heaters.values(): heater.set_temp(print_time, 0.) - def get_all_heaters(self): - return self.heaters.values() - def get_heater_by_gcode_id(self, gcode_id): - if gcode_id in self.heaters_gcode_id: - heater_name = self.heaters_gcode_id[gcode_id] - return self.heaters[heater_name] - return None def add_printer_objects(config): config.get_printer().add_object('heater', PrinterHeaters(config)) -- cgit v1.2.3-70-g09d2