diff --git a/docs/CANBUS.md b/docs/CANBUS.md
index 651ed4c9..e80141a9 100644
--- a/docs/CANBUS.md
+++ b/docs/CANBUS.md
@@ -135,3 +135,7 @@ iface can0 can static
be configured in Klipper's printer.cfg file with a `serial:`
parameter. The bridge board appears as a "USB CAN adapter" and it is
configured in the printer.cfg as a [CAN node](#configuring-klipper).
+
+## Tips for troubleshooting
+
+See the [CAN bus troubleshooting](CANBUS_Troubleshooting.md) document.
diff --git a/docs/CANBUS_Troubleshooting.md b/docs/CANBUS_Troubleshooting.md
new file mode 100644
index 00000000..2991d72c
--- /dev/null
+++ b/docs/CANBUS_Troubleshooting.md
@@ -0,0 +1,114 @@
+# CANBUS Troubleshooting
+
+This document provides information on troubleshooting communication
+issues when using [Klipper with CAN bus](CANBUS.md).
+
+## Verify CAN bus wiring
+
+The first step in troubleshooting communication issues is to verify
+the CAN bus wiring.
+
+Be sure there are exactly two 120 Ohm [terminating
+resistors](CANBUS.md#terminating-resistors) on the CAN bus. If the
+resistors are not properly installed then messages may not be able to
+be sent at all or the connection may have sporadic instability.
+
+The CANH and CANL bus wiring should be twisted around each other. At a
+minimum, the wiring should have a twist every few centimeters. Avoid
+twisting the CANH and CANL wiring around power wires and ensure that
+power wires that travel parallel to the CANH and CANL wires do not
+have the same amount of twists.
+
+Verify that all plugs and wire crimps on the CAN bus wiring are fully
+secured. Movement of the printer toolhead may jostle the CAN bus
+wiring causing a bad wire crimp or unsecured plug to result in
+intermittent communication errors.
+
+## Check for incrementing bytes_invalid counter
+
+The Klipper log file will report a `Stats` line once a second when the
+printer is active. These "Stats" lines will have a `bytes_invalid`
+counter for each micro-controller. This counter should not increment
+during normal printer operation (it is normal for the counter to be
+non-zero after a RESTART and it is not a concern if the counter
+increments once a month or so). If this counter increments on a CAN
+bus micro-controller during normal printing (it increments every few
+hours or more frequently) then it is an indication of a severe
+problem.
+
+Incrementing `bytes_invalid` on a CAN bus connection is a symptom of
+reordered messages on the CAN bus. There are two known causes of
+reordered messages:
+1. Old versions of the popular candlight_firmware for USB CAN adapters
+ had a bug that could cause reordered messages. If using a USB CAN
+ adapter running this firmware then make sure to update to the
+ latest firmware if incrementing `bytes_invalid` is observed.
+2. Some Linux kernel builds for embedded devices have been known to
+ reorder CAN bus messages. It may be necessary to use an alternative
+ Linux kernel or to use alternative hardware that supports
+ mainstream Linux kernels that do not exhibit this problem.
+
+Reordered messages is a severe problem that must be fixed. It will
+result in unstable behavior and can lead to confusing errors at any
+part of a print.
+
+## Obtaining candump logs
+
+The CAN bus messages sent to and from the micro-controller are handled
+by the Linux kernel. It is possible to capture these messages from the
+kernel for debugging purposes. A log of these messages may be of use
+in diagnostics.
+
+The Linux [can-utils](https://github.com/linux-can/can-utils) tool
+provides the capture software. It is typically installed on a machine
+by running:
+```
+sudo apt-get update && sudo apt-get install can-utils
+```
+
+Once installed, one may obtain a capture of all CAN bus messages on an
+interface with the following command:
+```
+candump -tz -Ddex can0,#FFFFFFFF > mycanlog
+```
+
+One can view the resulting log file (`mycanlog` in the example above)
+to see each raw CAN bus message that was sent and received by Klipper.
+Understanding the content of these messages will likely require
+low-level knowledge of Klipper's [CANBUS protocol](CANBUS_protocol.md)
+and Klipper's [MCU commands](MCU_Commands.md).
+
+## Using a logic analyzer on the canbus wiring
+
+The [Sigrok Pulseview](https://sigrok.org/wiki/PulseView) software
+along with a low-cost
+[logic analyzer](https://en.wikipedia.org/wiki/Logic_analyzer) can be
+useful for diagnosing CAN bus signaling. This is an advanced topic
+likely only of interest to experts.
+
+One can often find "USB logic analyzers" for under $15 (US pricing as
+of 2023). These devices are often listed as "Saleae logic clones" or
+as "24MHz 8 channel USB logic analyzers".
+
+![pulseview-canbus](img/pulseview-canbus.png)
+
+The above picture was taken while using Pulseview with a "Saleae
+clone" logic analyzer. The Sigrok and Pulseview software was installed
+on a desktop machine (also install the "fx2lafw" firmware if that is
+packaged separately). The CH0 pin on the logic analyzer was routed to
+the CAN Rx line, the CH1 pin was wired to the CAN Tx pin, and GND was
+wired to GND. Pulseview was configured to only display the D0 and D1
+lines (red "probe" icon center top toolbar). The number of samples was
+set to 5 million (top toolbar) and the sample rate was set to 24Mhz
+(top toolbar). The CAN decoder was added (yellow and green "bubble
+icon" right top toolbar). The D0 channel was labeled as RX and set to
+trigger on a falling edge (click on black D0 label at left). The D1
+channel was labeled as TX (click on brown D1 label at left). The CAN
+decoder was configured for 1Mbit rate (click on green CAN label at
+left). The CAN decoder was moved to the top of the display (click and
+drag green CAN label). Finally, the capture was started (click "Run"
+at top left) and a packet was transmitted on the CAN bus (`cansend
+can0 123#121212121212`).
+
+The logic analyzer provides an independent tool for capturing packets
+and verifying bit timing.
diff --git a/docs/Overview.md b/docs/Overview.md
index 9b94b01e..993061c4 100644
--- a/docs/Overview.md
+++ b/docs/Overview.md
@@ -92,5 +92,7 @@ communication with the Klipper developers.
- [Bootloaders](Bootloaders.md): Developer information on
micro-controller flashing.
- [CAN bus](CANBUS.md): Information on using CAN bus with Klipper.
+ - [CAN bus troubleshooting](CANBUS_Troubleshooting.md): Tips for
+ troubleshooting CAN bus.
- [TSL1401CL filament width sensor](TSL1401CL_Filament_Width_Sensor.md)
- [Hall filament width sensor](Hall_Filament_Width_Sensor.md)
diff --git a/docs/_klipper3d/mkdocs.yml b/docs/_klipper3d/mkdocs.yml
index 29c0bdd0..72bcb33c 100644
--- a/docs/_klipper3d/mkdocs.yml
+++ b/docs/_klipper3d/mkdocs.yml
@@ -133,6 +133,7 @@ nav:
- Beaglebone.md
- Bootloaders.md
- CANBUS.md
+ - CANBUS_Troubleshooting.md
- TSL1401CL_Filament_Width_Sensor.md
- Hall_Filament_Width_Sensor.md
- Sponsors.md
diff --git a/docs/img/pulseview-canbus.png b/docs/img/pulseview-canbus.png
new file mode 100644
index 00000000..3413edcf
--- /dev/null
+++ b/docs/img/pulseview-canbus.png
Binary files differ